Installation Instruction for Flange or Flange Adaptor

Flange adaptor (Flange adaptor, threaded flange, flange) can be used for the transitional connection between the grooved pipe and the equipment & valves with flanges. The diameter, location and measurement of the bolt hole on Flange adaptor are matching the bolts of international standards (GB9114. 9115. 9116. 9119. 9123-88)

1. Before installation, whether the groove meet the standard should be checked and then wipe away the pickles, iron rust, greasy dirt on gasket ring and pipe.

图片1

2. Assemble one part of flange on the pipe, and keep it in the groove of pipe.

图片2

3. Put another part of flange in the groove, screw the bolts and nuts averagely on the two parts.

图片3

4. Check the gasket to keep the availability in any situation, spread lubricant on surface of gasket.

图片4

5. Assemble gasket in the pipe OD and flange groove, to keep the gasket in right orientation.

图片5

6. Secure the bolts and refer to Table 5 for Bolt-Torque.

图片6

7. Insert standard bolts in bolt holes.

图片7

8. Insert standard bolts in the mated flange holes and screw nuts on them.

图片8

9. Secure the nuts and refer to Table 5 for Bolt-Torque.

图片9